FRU 360 {300m3/h)-50HZ, 360m3/h-60HZ}
Design Features
- Saved energy consumption by reduced operating time by inhaling from ambient pressure.
- Steady and excellent performance and applicable in all vacuum applications.
- Air-cooling system
- The pump have two outlet port, vertical and horizontal, to enable convenient piping with backing pump
- ISO flange is used for inlet and outlet port
- Low vibration level, low noise level
- Easy maintenance and repairing
Design Operation Principle
Based on the simple technology, they are made of a couple of Two-lobe rotating in opposite directions in a stator. Due to the lobe shape of the rotors and to the synchronization of their rotation through a pair of gears, these rotors remain permanently tangent to each other and tangent to the stator. FRU series is suited to a wide range of vacuum applications combined with primary vane pumps, piston pump or dry pumps.
Technical Data
Description | Unit | FRU 360 | ||
Displacement speed | 50Hz | m3/h | 300 | |
60Hz | 360 | |||
Ultimate pressurewith 2 stage backing pump | torr | 5 x 10-5 | ||
Inlet pressure(max. continuous) | torr | 760 | ||
Inlet port | ISO | 63 | ||
Outlet port | ISO | 63 | ||
Motor | Power | kW | 1.1 | |
Voltage | 50Hz | Volt | 220/380~420 | |
60Hz | 220/380/440 | |||
Rotational speedof pump | 50Hz | R.P.M | 3000 | |
60Hz | 3600 | |||
Oil filling | Liter | 0.6 | ||
Weight | kg | 105 |
Pumping Speed Curve
Design Features
Outside Dimension
(unit:mm)
Model | A | B | C | D | E | F | G | H | I | J | K | L | M | N |
FRU360 | 797 | 287 | 299 | 298 | 210 | 117 | 266 | 145 | 120 | 120 | 127 | Ø13 |
Dimensions of ISO flange
(unit:mm)
Standard | a | b | n | d |
ISO63 | 130 | 110 | 4 | M8 |
ISO100 | 165 | 145 | 8 | M8 |
ISO160 | 225 | 200 | 8 | M10 |
ISO200 | 285 | 260 | 12 | M10 |
ISO250 | 335 | 310 | 12 | M10 |